My Quote Request
5925-01-526-0133
20 Products
2310-701-02
CIRCUIT BREAKER
NSN, MFG P/N
5925015260133
NSN
5925-01-526-0133
MFG
AUTOMATIC TERMINAL INFORMATION SYSTEMS INC DBA ATIS
Description
III END ITEM IDENTIFICATION: LOAD CENTER
III PART NAME ASSIGNED BY CONTROLLING AGENCY: MULTI-FUNCTION MONITOR
Related Searches:
495182
CIRCUIT BREAKER
NSN, MFG P/N
5925015260463
NSN
5925-01-526-0463
MFG
MILLER ELECTRIC MFG CO
Description
III END ITEM IDENTIFICATION: ELECTRICAL GENERATOR GROUP
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 25.0 AMPERES AC ALL LOCATIONS
Related Searches:
495246
CIRCUIT BREAKER
NSN, MFG P/N
5925015260465
NSN
5925-01-526-0465
MFG
MILLER ELECTRIC MFG CO
Description
III END ITEM IDENTIFICATION: ELECTRICAL GENERATOR GROUP
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES AC ALL LOCATIONS
Related Searches:
2310-701-02(5K)
CIRCUIT BREAKER
NSN, MFG P/N
5925015260481
NSN
5925-01-526-0481
MFG
AUTOMATIC TERMINAL INFORMATION SYSTEMS INC DBA ATIS
Description
III END ITEM IDENTIFICATION: LOAD CENTER
III PART NAME ASSIGNED BY CONTROLLING AGENCY: MULTI-FUNCTION MONITOR
Related Searches:
PL9902A1009-1 ITEM 29
CIRCUIT BREAKER
NSN, MFG P/N
5925015260483
NSN
5925-01-526-0483
PL9902A1009-1 ITEM 29
CIRCUIT BREAKER
NSN, MFG P/N
5925015260483
NSN
5925-01-526-0483
MFG
L-3 COMMUNICATIONS WESTWOOD CORPORATION DBA EDI DIVISION DIV TANO DIVISION USE CAGE CODE 23905 FOR CATALOGING.
Description
III END ITEM IDENTIFICATION: LOAD CENTER
III PART NAME ASSIGNED BY CONTROLLING AGENCY: MULTI-FUNCTION MONITOR
Related Searches:
G-3261
CIRCUIT BREAKER
NSN, MFG P/N
5925015260725
NSN
5925-01-526-0725
MFG
HENSCHEL INC. DBA L-3 HENSCHEL
Description
BODY LENGTH: 2.000 INCHES NOMINAL
BODY STYLE: 1B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.515 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.530 INCHES NOMINAL
III END ITEM IDENTIFICATION: CONTROL UNIT, ICSU. VIRGINIA CLASS SUBMARINE, SSN-774.
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.200 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY: 2 SCREW
Related Searches:
SE105-BD-MMA-010 FIG 7-3-15
CIRCUIT BREAKER
NSN, MFG P/N
5925015260725
NSN
5925-01-526-0725
SE105-BD-MMA-010 FIG 7-3-15
CIRCUIT BREAKER
NSN, MFG P/N
5925015260725
NSN
5925-01-526-0725
MFG
NAVAL SEA SYSTEMS COMMAND
Description
BODY LENGTH: 2.000 INCHES NOMINAL
BODY STYLE: 1B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.515 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.530 INCHES NOMINAL
III END ITEM IDENTIFICATION: CONTROL UNIT, ICSU. VIRGINIA CLASS SUBMARINE, SSN-774.
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.200 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY: 2 SCREW
Related Searches:
AP12-0
CIRCUIT BREAKER
NSN, MFG P/N
5925015260726
NSN
5925-01-526-0726
MFG
SENSATA TECHNOLOGIES MARYLAND INC
Description
BODY LENGTH: 1.562 INCHES MAXIMUM
BODY STYLE: 1B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.281 INCHES MAXIMUM
BUSHING LENGTH: 0.380 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.875 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.625 INCHES MAXIMUM
III PART NAME ASSIGNED BY CONTROLLING AGENCY: MULTI-POLE CIRCUIT BREAKERS
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MOUNTING FACILITY TYPE AND QUANTITY: 3 THREADED BUSHING W/PANEL SEAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.780 INCHES MAXIMUM
POLE QUANTITY: 2
SPECIAL FEATURES: CONSISTS OF TWO INDEPENDENT SERIES TRIP BREAKERS, EACH AVAILABLE WITH ITS OWN RATING AND DELAY CHARACTERISTICS
Related Searches:
CEG6-1REC4-52-50.0-01
CIRCUIT BREAKER
NSN, MFG P/N
5925015261253
NSN
5925-01-526-1253
CEG6-1REC4-52-50.0-01
CIRCUIT BREAKER
NSN, MFG P/N
5925015261253
NSN
5925-01-526-1253
MFG
SENSATA TECHNOLOGIES MARYLAND INC
Description
ACTUATOR FUNCTION: TRIP-RESET
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 50.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 80.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
Related Searches:
CEG6-1REC4-52-50.0-1
CIRCUIT BREAKER
NSN, MFG P/N
5925015261253
NSN
5925-01-526-1253
MFG
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
ACTUATOR FUNCTION: TRIP-RESET
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 50.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 80.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
Related Searches:
LELK1-1REC4-320661V
CIRCUIT BREAKER
NSN, MFG P/N
5925015261254
NSN
5925-01-526-1254
MFG
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
ACTUATOR FUNCTION: TRIP-RESET
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT SECOND LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 100.0 AMPERES DC SECOND LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 15.0 DC FIRST LOCATION 80.0 DC SECOND LOCATION
POLE QUANTITY: 2
RESET METHOD: MANUAL
TRIP RELEASE CHARACTERISTIC: TIME DELAY SECOND LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
Related Searches:
LELK11-1REC4-32066-1-V
CIRCUIT BREAKER
NSN, MFG P/N
5925015261254
NSN
5925-01-526-1254
LELK11-1REC4-32066-1-V
CIRCUIT BREAKER
NSN, MFG P/N
5925015261254
NSN
5925-01-526-1254
MFG
SENSATA TECHNOLOGIES MARYLAND INC
Description
ACTUATOR FUNCTION: TRIP-RESET
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT SECOND LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 100.0 AMPERES DC SECOND LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 15.0 DC FIRST LOCATION 80.0 DC SECOND LOCATION
POLE QUANTITY: 2
RESET METHOD: MANUAL
TRIP RELEASE CHARACTERISTIC: TIME DELAY SECOND LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
Related Searches:
CEG6-1REC4-52-15.0-01
CIRCUIT BREAKER
NSN, MFG P/N
5925015261258
NSN
5925-01-526-1258
CEG6-1REC4-52-15.0-01
CIRCUIT BREAKER
NSN, MFG P/N
5925015261258
NSN
5925-01-526-1258
MFG
SENSATA TECHNOLOGIES MARYLAND INC
Description
ACTUATOR FUNCTION: TRIP-RESET
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 80.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
Related Searches:
CEG6-1REC4-52-15.0-1
CIRCUIT BREAKER
NSN, MFG P/N
5925015261258
NSN
5925-01-526-1258
MFG
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
ACTUATOR FUNCTION: TRIP-RESET
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 80.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
Related Searches:
CEG6-1REC4-52-5.0-1
CIRCUIT BREAKER
NSN, MFG P/N
5925015261259
NSN
5925-01-526-1259
MFG
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
ACTUATOR FUNCTION: TRIP-RESET
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 5.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 80.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
Related Searches:
CEG6-1REC4-52-5.00-01
CIRCUIT BREAKER
NSN, MFG P/N
5925015261259
NSN
5925-01-526-1259
CEG6-1REC4-52-5.00-01
CIRCUIT BREAKER
NSN, MFG P/N
5925015261259
NSN
5925-01-526-1259
MFG
SENSATA TECHNOLOGIES MARYLAND INC
Description
ACTUATOR FUNCTION: TRIP-RESET
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 5.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 80.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
Related Searches:
M55629/1-281
CIRCUIT BREAKER
NSN, MFG P/N
5925015261284
NSN
5925-01-526-1284
MFG
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
BODY LENGTH: 25.530 INCHES MAXIMUM
BODY STYLE: 12A SINGLE POLE TYPE
BODY WIDTH: 0.730 INCHES MINIMUM AND 0.775 INCHES MAXIMUM
BOSS HEIGHT: 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
CASE MATERIAL: CERAMIC OR MICA OR PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M55629/1-281
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 1.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.553 INCHES MAXIMUM
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-55629/1
OPERATING VOLTAGE TYPE AND
Related Searches:
CEG6-1REC4-52-30.0-01
CIRCUIT BREAKER
NSN, MFG P/N
5925015261443
NSN
5925-01-526-1443
CEG6-1REC4-52-30.0-01
CIRCUIT BREAKER
NSN, MFG P/N
5925015261443
NSN
5925-01-526-1443
MFG
SENSATA TECHNOLOGIES MARYLAND INC
Description
ACTUATOR FUNCTION: TRIP-RESET
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 30.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 80.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
Related Searches:
CEG6-1REC4-52-30.0-1
CIRCUIT BREAKER
NSN, MFG P/N
5925015261443
NSN
5925-01-526-1443
MFG
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
ACTUATOR FUNCTION: TRIP-RESET
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 30.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 80.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
Related Searches:
PCD0900001-0115
CIRCUIT BREAKER
NSN, MFG P/N
5925015261649
NSN
5925-01-526-1649
MFG
CAE USA INC. DIV SIMULATOR PRODUCTS DIVISION
Description
III END ITEM IDENTIFICATION: FLIGHT SIMULATOR, CAE USA, MODEL RAN SH-2G (A)