My Quote Request
5970-00-992-3470
20 Products
SS7073-1801
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923470
NSN
5970-00-992-3470
SS7073-1801
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923470
NSN
5970-00-992-3470
MFG
SIKORSKY AIRCRAFT CORPORATION
Description
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
Related Searches:
62A5A142-2
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923470
NSN
5970-00-992-3470
62A5A142-2
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923470
NSN
5970-00-992-3470
MFG
NAVAL AIR SYSTEMS COMMAND
Description
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
Related Searches:
908145-1
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923470
NSN
5970-00-992-3470
908145-1
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923470
NSN
5970-00-992-3470
MFG
MEGGITT DEFENSE SYSTEMS INC.
Description
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
Related Searches:
91455318
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923470
NSN
5970-00-992-3470
91455318
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923470
NSN
5970-00-992-3470
MFG
THALES
Description
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
Related Searches:
B10175
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923470
NSN
5970-00-992-3470
B10175
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923470
NSN
5970-00-992-3470
MFG
MBDA UK LTD
Description
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
Related Searches:
C5072305
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923470
NSN
5970-00-992-3470
C5072305
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923470
NSN
5970-00-992-3470
MFG
US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR
Description
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
Related Searches:
C5075979-10
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923470
NSN
5970-00-992-3470
C5075979-10
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923470
NSN
5970-00-992-3470
MFG
SIGNALS WARFARE PROJECT MANAGER
Description
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
Related Searches:
FV2044230/4
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923470
NSN
5970-00-992-3470
FV2044230/4
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923470
NSN
5970-00-992-3470
MFG
QINETIQ
Description
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
Related Searches:
GS830AE2-3
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923470
NSN
5970-00-992-3470
GS830AE2-3
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923470
NSN
5970-00-992-3470
MFG
NORTHROP GRUMMAN SYSTEMS CORPORATION DIV NORTHROP GRUMMAN AEROSPACE SYSTEMS
Description
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
Related Searches:
LS9751-5
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923470
NSN
5970-00-992-3470
LS9751-5
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923470
NSN
5970-00-992-3470
MFG
LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN
Description
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
Related Searches:
11324392-3
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923472
NSN
5970-00-992-3472
11324392-3
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923472
NSN
5970-00-992-3472
MFG
BALLISTIC MISSILE DEFENSE SYSTEMS COMMAND
Description
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG: 10.0 NOMINAL AS SUPPLIED 30.0 NOMINAL AFTER UNRESTRICTED RECOVERY
COLOR: BLACK
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS: 200.0 VOLTS PER MIL /0.001 INCH/
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES: 3.500 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH: 4.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ENVIRONMENTAL PROTECTION: CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT
FIRST BRANCH INSIDE DIAMETER: 1.060 INCHES MINIMUM AS SUPPLIED 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH WALL THICKNESS: 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITY: SEMIRIGID
MAIN BODY INSIDE DIAMETER: 2.190 INCHES MINIMUM AS SUPPLIED 1.000 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY OVERALL LENGTH: 7.560 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS: 0.180 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIAL: PLASTIC, POLYOLEFIN, RT-301, RAYCHEM CORP OR PLASTIC,POLYOLEFIN,MPP-262,3M CO
MINIMUM TENSILE STRENGTH: 1500 POUNDS PER SQUARE INCH
RELIABILITY INDICATOR: NOT ESTABLISHED
SECOND BRANCH INSIDE DIAMETER: 1.060 INCHES MINIMUM AS SUPPLIED 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH WALL THICKNESS: 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
STYLE DESIGNATOR: B8 TRANSITION-1 TO 3 CABLES
TEMP RATING: -55.0 DEG CELSIUS
THIRD BRANCH INSIDE DIAMETER: 1.060 INCHES MINIMUM AS SUPPLIED 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH WALL THICKNESS: 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
Related Searches:
11732656
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923472
NSN
5970-00-992-3472
11732656
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923472
NSN
5970-00-992-3472
MFG
U S ARMY ARMAMENT RESEARCH & DEVELOPMENT COMMAND
Description
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG: 10.0 NOMINAL AS SUPPLIED 30.0 NOMINAL AFTER UNRESTRICTED RECOVERY
COLOR: BLACK
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS: 200.0 VOLTS PER MIL /0.001 INCH/
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES: 3.500 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH: 4.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ENVIRONMENTAL PROTECTION: CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT
FIRST BRANCH INSIDE DIAMETER: 1.060 INCHES MINIMUM AS SUPPLIED 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH WALL THICKNESS: 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITY: SEMIRIGID
MAIN BODY INSIDE DIAMETER: 2.190 INCHES MINIMUM AS SUPPLIED 1.000 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY OVERALL LENGTH: 7.560 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS: 0.180 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIAL: PLASTIC, POLYOLEFIN, RT-301, RAYCHEM CORP OR PLASTIC,POLYOLEFIN,MPP-262,3M CO
MINIMUM TENSILE STRENGTH: 1500 POUNDS PER SQUARE INCH
RELIABILITY INDICATOR: NOT ESTABLISHED
SECOND BRANCH INSIDE DIAMETER: 1.060 INCHES MINIMUM AS SUPPLIED 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH WALL THICKNESS: 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
STYLE DESIGNATOR: B8 TRANSITION-1 TO 3 CABLES
TEMP RATING: -55.0 DEG CELSIUS
THIRD BRANCH INSIDE DIAMETER: 1.060 INCHES MINIMUM AS SUPPLIED 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH WALL THICKNESS: 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
Related Searches:
202-25204SP4
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923472
NSN
5970-00-992-3472
202-25204SP4
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923472
NSN
5970-00-992-3472
MFG
VOUGHT AIRCRAFT INDUSTRIES INC.
Description
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG: 10.0 NOMINAL AS SUPPLIED 30.0 NOMINAL AFTER UNRESTRICTED RECOVERY
COLOR: BLACK
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS: 200.0 VOLTS PER MIL /0.001 INCH/
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES: 3.500 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH: 4.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ENVIRONMENTAL PROTECTION: CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT
FIRST BRANCH INSIDE DIAMETER: 1.060 INCHES MINIMUM AS SUPPLIED 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH WALL THICKNESS: 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITY: SEMIRIGID
MAIN BODY INSIDE DIAMETER: 2.190 INCHES MINIMUM AS SUPPLIED 1.000 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY OVERALL LENGTH: 7.560 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS: 0.180 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIAL: PLASTIC, POLYOLEFIN, RT-301, RAYCHEM CORP OR PLASTIC,POLYOLEFIN,MPP-262,3M CO
MINIMUM TENSILE STRENGTH: 1500 POUNDS PER SQUARE INCH
RELIABILITY INDICATOR: NOT ESTABLISHED
SECOND BRANCH INSIDE DIAMETER: 1.060 INCHES MINIMUM AS SUPPLIED 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH WALL THICKNESS: 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
STYLE DESIGNATOR: B8 TRANSITION-1 TO 3 CABLES
TEMP RATING: -55.0 DEG CELSIUS
THIRD BRANCH INSIDE DIAMETER: 1.060 INCHES MINIMUM AS SUPPLIED 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH WALL THICKNESS: 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
Related Searches:
311-1-B7
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923472
NSN
5970-00-992-3472
311-1-B7
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923472
NSN
5970-00-992-3472
MFG
HELLERMANNTYTON LIMITED
Description
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG: 10.0 NOMINAL AS SUPPLIED 30.0 NOMINAL AFTER UNRESTRICTED RECOVERY
COLOR: BLACK
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS: 200.0 VOLTS PER MIL /0.001 INCH/
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES: 3.500 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH: 4.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ENVIRONMENTAL PROTECTION: CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT
FIRST BRANCH INSIDE DIAMETER: 1.060 INCHES MINIMUM AS SUPPLIED 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH WALL THICKNESS: 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITY: SEMIRIGID
MAIN BODY INSIDE DIAMETER: 2.190 INCHES MINIMUM AS SUPPLIED 1.000 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY OVERALL LENGTH: 7.560 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS: 0.180 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIAL: PLASTIC, POLYOLEFIN, RT-301, RAYCHEM CORP OR PLASTIC,POLYOLEFIN,MPP-262,3M CO
MINIMUM TENSILE STRENGTH: 1500 POUNDS PER SQUARE INCH
RELIABILITY INDICATOR: NOT ESTABLISHED
SECOND BRANCH INSIDE DIAMETER: 1.060 INCHES MINIMUM AS SUPPLIED 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH WALL THICKNESS: 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
STYLE DESIGNATOR: B8 TRANSITION-1 TO 3 CABLES
TEMP RATING: -55.0 DEG CELSIUS
THIRD BRANCH INSIDE DIAMETER: 1.060 INCHES MINIMUM AS SUPPLIED 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH WALL THICKNESS: 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
Related Searches:
462A046-3
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923472
NSN
5970-00-992-3472
462A046-3
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923472
NSN
5970-00-992-3472
MFG
TYCO ELECTRONICS CORPORATION DIV RAYCHEM
Description
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG: 10.0 NOMINAL AS SUPPLIED 30.0 NOMINAL AFTER UNRESTRICTED RECOVERY
COLOR: BLACK
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS: 200.0 VOLTS PER MIL /0.001 INCH/
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES: 3.500 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH: 4.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ENVIRONMENTAL PROTECTION: CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT
FIRST BRANCH INSIDE DIAMETER: 1.060 INCHES MINIMUM AS SUPPLIED 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH WALL THICKNESS: 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITY: SEMIRIGID
MAIN BODY INSIDE DIAMETER: 2.190 INCHES MINIMUM AS SUPPLIED 1.000 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY OVERALL LENGTH: 7.560 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS: 0.180 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIAL: PLASTIC, POLYOLEFIN, RT-301, RAYCHEM CORP OR PLASTIC,POLYOLEFIN,MPP-262,3M CO
MINIMUM TENSILE STRENGTH: 1500 POUNDS PER SQUARE INCH
RELIABILITY INDICATOR: NOT ESTABLISHED
SECOND BRANCH INSIDE DIAMETER: 1.060 INCHES MINIMUM AS SUPPLIED 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH WALL THICKNESS: 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
STYLE DESIGNATOR: B8 TRANSITION-1 TO 3 CABLES
TEMP RATING: -55.0 DEG CELSIUS
THIRD BRANCH INSIDE DIAMETER: 1.060 INCHES MINIMUM AS SUPPLIED 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH WALL THICKNESS: 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
Related Searches:
573H157-1
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923472
NSN
5970-00-992-3472
573H157-1
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923472
NSN
5970-00-992-3472
MFG
MINNESOTA MINING AND MFG CO 3M COMPANY
Description
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG: 10.0 NOMINAL AS SUPPLIED 30.0 NOMINAL AFTER UNRESTRICTED RECOVERY
COLOR: BLACK
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS: 200.0 VOLTS PER MIL /0.001 INCH/
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES: 3.500 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH: 4.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ENVIRONMENTAL PROTECTION: CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT
FIRST BRANCH INSIDE DIAMETER: 1.060 INCHES MINIMUM AS SUPPLIED 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH WALL THICKNESS: 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITY: SEMIRIGID
MAIN BODY INSIDE DIAMETER: 2.190 INCHES MINIMUM AS SUPPLIED 1.000 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY OVERALL LENGTH: 7.560 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS: 0.180 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIAL: PLASTIC, POLYOLEFIN, RT-301, RAYCHEM CORP OR PLASTIC,POLYOLEFIN,MPP-262,3M CO
MINIMUM TENSILE STRENGTH: 1500 POUNDS PER SQUARE INCH
RELIABILITY INDICATOR: NOT ESTABLISHED
SECOND BRANCH INSIDE DIAMETER: 1.060 INCHES MINIMUM AS SUPPLIED 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH WALL THICKNESS: 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
STYLE DESIGNATOR: B8 TRANSITION-1 TO 3 CABLES
TEMP RATING: -55.0 DEG CELSIUS
THIRD BRANCH INSIDE DIAMETER: 1.060 INCHES MINIMUM AS SUPPLIED 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH WALL THICKNESS: 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
Related Searches:
6011GEEEP
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923472
NSN
5970-00-992-3472
6011GEEEP
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923472
NSN
5970-00-992-3472
MFG
TYCO ELECTRONICS CORPORATION DIV RAYCHEM
Description
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG: 10.0 NOMINAL AS SUPPLIED 30.0 NOMINAL AFTER UNRESTRICTED RECOVERY
COLOR: BLACK
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS: 200.0 VOLTS PER MIL /0.001 INCH/
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES: 3.500 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH: 4.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ENVIRONMENTAL PROTECTION: CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT
FIRST BRANCH INSIDE DIAMETER: 1.060 INCHES MINIMUM AS SUPPLIED 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH WALL THICKNESS: 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITY: SEMIRIGID
MAIN BODY INSIDE DIAMETER: 2.190 INCHES MINIMUM AS SUPPLIED 1.000 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY OVERALL LENGTH: 7.560 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS: 0.180 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIAL: PLASTIC, POLYOLEFIN, RT-301, RAYCHEM CORP OR PLASTIC,POLYOLEFIN,MPP-262,3M CO
MINIMUM TENSILE STRENGTH: 1500 POUNDS PER SQUARE INCH
RELIABILITY INDICATOR: NOT ESTABLISHED
SECOND BRANCH INSIDE DIAMETER: 1.060 INCHES MINIMUM AS SUPPLIED 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH WALL THICKNESS: 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
STYLE DESIGNATOR: B8 TRANSITION-1 TO 3 CABLES
TEMP RATING: -55.0 DEG CELSIUS
THIRD BRANCH INSIDE DIAMETER: 1.060 INCHES MINIMUM AS SUPPLIED 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH WALL THICKNESS: 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
Related Searches:
SS7073-1903
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923472
NSN
5970-00-992-3472
SS7073-1903
INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE
NSN, MFG P/N
5970009923472
NSN
5970-00-992-3472
MFG
SIKORSKY AIRCRAFT CORPORATION
Description
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG: 10.0 NOMINAL AS SUPPLIED 30.0 NOMINAL AFTER UNRESTRICTED RECOVERY
COLOR: BLACK
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS: 200.0 VOLTS PER MIL /0.001 INCH/
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES: 3.500 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH: 4.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ENVIRONMENTAL PROTECTION: CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT
FIRST BRANCH INSIDE DIAMETER: 1.060 INCHES MINIMUM AS SUPPLIED 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH WALL THICKNESS: 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITY: SEMIRIGID
MAIN BODY INSIDE DIAMETER: 2.190 INCHES MINIMUM AS SUPPLIED 1.000 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY OVERALL LENGTH: 7.560 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS: 0.180 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIAL: PLASTIC, POLYOLEFIN, RT-301, RAYCHEM CORP OR PLASTIC,POLYOLEFIN,MPP-262,3M CO
MINIMUM TENSILE STRENGTH: 1500 POUNDS PER SQUARE INCH
RELIABILITY INDICATOR: NOT ESTABLISHED
SECOND BRANCH INSIDE DIAMETER: 1.060 INCHES MINIMUM AS SUPPLIED 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH WALL THICKNESS: 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
STYLE DESIGNATOR: B8 TRANSITION-1 TO 3 CABLES
TEMP RATING: -55.0 DEG CELSIUS
THIRD BRANCH INSIDE DIAMETER: 1.060 INCHES MINIMUM AS SUPPLIED 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH WALL THICKNESS: 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
Related Searches:
178871
INSULATOR,BUSHING
NSN, MFG P/N
5970009924085
NSN
5970-00-992-4085
MFG
TELEMECHANICS INC
Description
INSIDE DIAMETER: 0.500 INCHES NOMINAL
OVERALL HEIGHT: 1.125 INCHES NOMINAL
STYLE DESIGNATOR: C1 CYLINDRICAL
Related Searches:
41611-501-3
INSULATOR,ARMAMENT
NSN, MFG P/N
5970009926270
NSN
5970-00-992-6270
MFG
BOEING COMPANY THE DBA BOEING DIV DEFENSE SPACE & SECURITY - NETWORK & SPACE SYSTEMS
Description
INSULATOR,ARMAMENT