My Quote Request
5925-01-499-5951
20 Products
FCP34015-1366
CIRCUIT BREAKER
NSN, MFG P/N
5925014995951
NSN
5925-01-499-5951
MFG
U S DEPT OF TRANSPORTATION FEDERAL AVIATION ADMINISTRATION
Description
III END ITEM IDENTIFICATION: DUAL REDUNDANT POWER DISTRIBUTION SYSTEM (DRPDS)
Related Searches:
AM3R-C8-D-AA-02-D-A-30-03
CIRCUIT BREAKER
NSN, MFG P/N
5925014985089
NSN
5925-01-498-5089
AM3R-C8-D-AA-02-D-A-30-03
CIRCUIT BREAKER
NSN, MFG P/N
5925014985089
NSN
5925-01-498-5089
MFG
EATON CORP AEROSPACE COMMERCIAL CONTROLS DIV
Description
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.265 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: REVERSE PHASE ALL LOCATIONS
FREQUENCY IN HERTZ: 400.0 ALL LOCATIONS
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 30.0 AMPERES AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 THREADED HOLE
POLE QUANTITY: 3
RESET METHOD: MANUAL
SPECIAL FEATURES: HANDLE/ACTUATOR COLOR BLACK WITH WHITE MARKINGS
TERMINAL TYPE AND QUANTITY: 6 THREADED STUD
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
Related Searches:
UPGH-666-1-41-303-01
CIRCUIT BREAKER
NSN, MFG P/N
5925014985089
NSN
5925-01-498-5089
MFG
SENSATA TECHNOLOGIES MARYLAND INC
Description
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.265 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: REVERSE PHASE ALL LOCATIONS
FREQUENCY IN HERTZ: 400.0 ALL LOCATIONS
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 30.0 AMPERES AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 THREADED HOLE
POLE QUANTITY: 3
RESET METHOD: MANUAL
SPECIAL FEATURES: HANDLE/ACTUATOR COLOR BLACK WITH WHITE MARKINGS
TERMINAL TYPE AND QUANTITY: 6 THREADED STUD
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
Related Searches:
IULNK111REC5-28795-2
CIRCUIT BREAKER
NSN, MFG P/N
5925014987886
NSN
5925-01-498-7886
MFG
SENSATA TECHNOLOGIES MARYLAND INC
Description
FREQUENCY IN HERTZ: 50.0 OR 60.0 ALL LOCATIONS
III END ITEM IDENTIFICATION: 5840-01-450-8126
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 50.0 AMPERES AC ALL LOCATIONS
POLE QUANTITY: 3
Related Searches:
52015
CIRCUIT BREAKER
NSN, MFG P/N
5925014988486
NSN
5925-01-498-8486
MFG
ANCOR PRODUCTS INC PRECISION LIGHTING DIV
Description
SPECIAL FEATURES: 15 AMP D0UBLE BREAKER3AGAVG23 FT USCG WORKBOAT, MODEL/PART NO. 583-01-61
Related Searches:
51050
CIRCUIT BREAKER
NSN, MFG P/N
5925014988542
NSN
5925-01-498-8542
MFG
ANCOR PRODUCTS INC PRECISION LIGHTING DIV
Description
III END ITEM IDENTIFICATION: 23 FOOT USCG WORKBOAT, MPDEL/PART NO. 583-01-61
SPECIAL FEATURES: 50 AMP BREAKER
Related Searches:
51020
CIRCUIT BREAKER
NSN, MFG P/N
5925014988545
NSN
5925-01-498-8545
MFG
ANCOR PRODUCTS INC PRECISION LIGHTING DIV
Description
III END ITEM IDENTIFICATION: 23 FT USCG WORKBOAT, PART/MODEL NO 583-01-61
SPECIAL FEATURES: 20 AMP BREAKER
Related Searches:
51015
CIRCUIT BREAKER
NSN, MFG P/N
5925014988546
NSN
5925-01-498-8546
MFG
ANCOR PRODUCTS INC PRECISION LIGHTING DIV
Description
III END ITEM IDENTIFICATION: 23 FT USCG WORKBOAT, PART/MODEL NO. 583-01-61
SPECIAL FEATURES: 15 AMP BREAKER
Related Searches:
51010
CIRCUIT BREAKER
NSN, MFG P/N
5925014988547
NSN
5925-01-498-8547
MFG
ANCOR PRODUCTS INC PRECISION LIGHTING DIV
Description
III END ITEM IDENTIFICATION: 23 FT USCG WORKBOAT, PART/MODEL NO. 583-01-61
SPECIAL FEATURES: 10 AMP BREAKER
Related Searches:
ETN-345300S31
CIRCUIT BREAKER
NSN, MFG P/N
5925014989062
NSN
5925-01-498-9062
MFG
SPD ELECTRICAL SYSTEMS INC
Description
BODY LENGTH: 9.000 INCHES NOMINAL
BODY STYLE: 4A SINGLE POLE TYPE
BODY WIDTH: 6.187 INCHES NOMINAL
III END ITEM IDENTIFICATION: CIRCUIT BREAKER AQB-LF402 350A 400FR
Related Searches:
ETN-345400S31
CIRCUIT BREAKER
NSN, MFG P/N
5925014989067
NSN
5925-01-498-9067
MFG
SPD ELECTRICAL SYSTEMS INC
Description
BODY LENGTH: 17.937 INCHES NOMINAL
BODY STYLE: 14B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 9.000 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERVOLTAGE ALL LOCATIONS
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III END ITEM IDENTIFICATION: CIRCUIT BREAKER AQB-LF402 400A 400FR
III PART NAME ASSIGNED BY CONTROLLING AGENCY: ACTRON CIRCUIT BREAKER
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 400.0 AMPERES AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 3 TERMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 500.0 AC ALL LOCATIONS
OVERALL HEIGHT: 11.000 INCHES NOMINAL
POLE QUANTITY: 3
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC OR THERMAL-MAGNETIC ALL LOCATIONS
Related Searches:
ETN-345420U01
CIRCUIT BREAKER
NSN, MFG P/N
5925014989068
NSN
5925-01-498-9068
MFG
SPD ELECTRICAL SYSTEMS INC
Description
BODY LENGTH: 17.937 INCHES NOMINAL
BODY STYLE: 14B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 9.000 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: UNDERVOLTAGE ALL LOCATIONS
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III END ITEM IDENTIFICATION: CIRCUIT BREAKER AQB-LF402 400FR
III PART NAME ASSIGNED BY CONTROLLING AGENCY: ACTRON CIRCUIT BREAKER
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 400.0 AMPERES AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 3 TERMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 500.0 AC ALL LOCATIONS
OVERALL HEIGHT: 11.000 INCHES NOMINAL
POLE QUANTITY: 3
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC OR THERMAL-MAGNETIC ALL LOCATIONS
Related Searches:
M39019/04-224S
CIRCUIT BREAKER
NSN, MFG P/N
5925014989992
NSN
5925-01-498-9992
MFG
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: BETWEEN POLE ONE AND TWO
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY LENGTH: 1.531 INCHES MINIMUM AND 1.562 INCHES MAXIMUM
BODY STYLE: 1B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.250 INCHES MINIMUM AND 1.281 INCHES MAXIMUM
BUSHING LENGTH: 0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM
CASE MATERIAL: METAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.875 INCHES MINIMUM AND 0.906 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M39019/04-224S
FREQUENCY IN HERTZ: 400.0 ALL LOCATIONS
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 100.0 GRAMS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND HERMETICALLY SEALED
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 3.0 AMPERES AC AND 3.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 300.0 AC AND 500.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING W/PANEL SEAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.797 INCHES MINIMUM AND 1.828 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.375 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-39019/4
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC AND 50.0 DC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-39019 PROFESSIONAL/INDUSTRIAL ASSOCIATION SPECIFICATION
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 120.0 AC AND 0.5 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE TWO
SWITCH TERMINAL TYPE: TAB W/SCREW
TERMINAL TYPE AND QUANTITY: 4 WIRE HOOK
TEST DATA DOCUMENT: 81349-MIL-C-39019 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNEF
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.055 MINIMUM AT 200 PCT AND 0.950 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
Related Searches:
209-3-1-65-3-9-100
CIRCUIT BREAKER
NSN, MFG P/N
5925014990421
NSN
5925-01-499-0421
MFG
AIRPAX CORP
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 5.125 INCHES NOMINAL
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 3.108 INCHES MAXIMUM
BOSS HEIGHT: 0.220 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 3.550 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 1.026 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.750 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.026 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FREQUENCY IN HERTZ: 50.0 OR 60.0 ALL LOCATIONS
III END ITEM IDENTIFICATION: SPACE LIFT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 3 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 100.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 3.550 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
SPECIAL FEATURES: BREAKER MAGNETIC
TERMINAL TYPE AND QUANTITY: 6 THREADED STUD
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 3.000 MINIMUM AT 200 PCT AND 15.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
Related Searches:
23E10
CIRCUIT BREAKER
NSN, MFG P/N
5925014993416
NSN
5925-01-499-3416
MFG
BACO CONTROLS INC
Description
III END ITEM IDENTIFICATION: 2320-01-432-4847, M-915 TRUCK
III PRECIOUS MATERIAL: SILVER
III PRECIOUS MATERIAL AND LOCATION: CONTACTS SILVER
POLE QUANTITY: 2
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, SINGLE THROW, NORMALLY OPEN
TERMINAL TYPE AND QUANTITY: 2 SCREW
Related Searches:
62828-40155-120
CIRCUIT BREAKER MOD
NSN, MFG P/N
5925014993765
NSN
5925-01-499-3765
MFG
NATIONAL WEATHER SERVICE DIV OFFICE OF HYDROLOGIC DEVELOPMENT
Description
III END ITEM IDENTIFICATION: AUTOMATED SURFACE OBSERVATION SYSTEM
III PART NAME ASSIGNED BY CONTROLLING AGENCY: MODULE,CIRCUIT BREAKER, DTS1, 3AMP
Related Searches:
BAN7016-515
CIRCUIT BREAKER
NSN, MFG P/N
5925014993815
NSN
5925-01-499-3815
MFG
EATON CORPORATION DBA FLUID POWER DIV DIV POWER AND LOAD MANAGEMENT SYSTEMS
Description
BODY STYLE: 17A SINGLE POLE TYPE
BODY WIDTH: 1.200 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.530 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.940 INCHES NOMINAL
III UNPACKAGED UNIT WEIGHT: 11.750 OUNCES
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 28.0 AMPERES DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 4.190 INCHES NOMINAL
OVERALL LENGTH: 3.250 INCHES NOMINAL
POLE QUANTITY: 1
SPECIAL FEATURES: NOMINAL SYSTEM VOLTAGE 28VDC (18 VOLTS MIN.) - 115 VAC 400HZ (104 VOLTSMIN)
Related Searches:
7-W11B11090-9
CIRCUIT BREAKER SUBASSEMBLY
NSN, MFG P/N
5925014995475
NSN
5925-01-499-5475
7-W11B11090-9
CIRCUIT BREAKER SUBASSEMBLY
NSN, MFG P/N
5925014995475
NSN
5925-01-499-5475
MFG
BOEING COMPANY THE DIV DEFENSE SPACE & SECURITY
Description
END ITEM IDENTIFICATION: LONGBOW APACHE WAH-64 HELICOPTER
Related Searches:
32845
CIRCUIT BREAKER
NSN, MFG P/N
5925014995669
NSN
5925-01-499-5669
MFG
U S DEPT OF TRANSPORTATION FEDERAL AVIATION ADMINISTRATION
Description
III END ITEM IDENTIFICATION: DUAL REDUNDANT POWER DISTRIBTUION SYSTEM (DRPDS)
Related Searches:
FC341001366
CIRCUIT BREAKER
NSN, MFG P/N
5925014995950
NSN
5925-01-499-5950
MFG
U S DEPT OF TRANSPORTATION FEDERAL AVIATION ADMINISTRATION
Description
III END ITEM IDENTIFICATION: DUAL REDUNDANT POWER DISTRIBUTION SYSTEM (DRPDS)