Featured Products

My Quote Request

No products added yet

5925-01-135-2025

20 Products

PS150-S

INTERRUPTER,GROUND FAULT

NSN, MFG P/N

5925011352025

NSN

5925-01-135-2025

View More Info

PS150-S

INTERRUPTER,GROUND FAULT

NSN, MFG P/N

5925011352025

NSN

5925-01-135-2025

MFG

PASS & SEYMOUR INC D IV PASS & SEYMOUR

Description

GENERAL CHARACTERISTICS ITEM DESCRIPTION: PORTABLE PLUG-IN UNIT; 120 VAC; 15 AMP; 5 MA; USED FOR TEMPORARY PROTECTION

3493

INTERRUPTER,GROUND FAULT

NSN, MFG P/N

5925011352025

NSN

5925-01-135-2025

View More Info

3493

INTERRUPTER,GROUND FAULT

NSN, MFG P/N

5925011352025

NSN

5925-01-135-2025

MFG

WOODHEAD LP DBA WOODHEAD DIV AUTOMATION & ELECTRICAL PRODUCTS DIVISION

Description

GENERAL CHARACTERISTICS ITEM DESCRIPTION: PORTABLE PLUG-IN UNIT; 120 VAC; 15 AMP; 5 MA; USED FOR TEMPORARY PROTECTION

GFP-15C

INTERRUPTER,GROUND FAULT

NSN, MFG P/N

5925011352025

NSN

5925-01-135-2025

View More Info

GFP-15C

INTERRUPTER,GROUND FAULT

NSN, MFG P/N

5925011352025

NSN

5925-01-135-2025

MFG

HUBBELL INC WIRING DEVICE DIV

Description

GENERAL CHARACTERISTICS ITEM DESCRIPTION: PORTABLE PLUG-IN UNIT; 120 VAC; 15 AMP; 5 MA; USED FOR TEMPORARY PROTECTION

238D674GR4

ARC SHUTE ASSEMBLY

NSN, MFG P/N

5925011353744

NSN

5925-01-135-3744

View More Info

238D674GR4

ARC SHUTE ASSEMBLY

NSN, MFG P/N

5925011353744

NSN

5925-01-135-3744

MFG

GENERAL ELECTRIC CO OUTDOOR BREAKER BUSINESS SECTION

935264-3

CIRCUIT BREAKER

NSN, MFG P/N

5925011354893

NSN

5925-01-135-4893

View More Info

935264-3

CIRCUIT BREAKER

NSN, MFG P/N

5925011354893

NSN

5925-01-135-4893

MFG

NORTHROP GRUMMAN GUIDANCE AND ELECTRONICS COMPANY INC. DBA NAVIGATION SYSTEMS DIVISION DIV NAVIGATION SYSTEMS DIVISION

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY LENGTH: 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM
BODY STYLE: 12A SINGLE POLE TYPE
BODY WIDTH: 0.750 INCHES MAXIMUM
BOSS HEIGHT: 0.135 INCHES MINIMUM AND 0.165 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.925 INCHES MINIMUM AND 1.955 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 3.700 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: CORROSION RESISTANT AND MOISTURE RESISTANT AND SHOCKPROOF AND VIBRATIONPROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 100.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 2000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.625 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 32.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 10.0 AC AND 3.0 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: PIN
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 250.0 AC AND 50.0 DC
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
THREAD PITCH DIAMETERS: 0.1177 TO 0.1214 INCHES
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.700 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

APL1-1RE-4349-3

CIRCUIT BREAKER

NSN, MFG P/N

5925011354893

NSN

5925-01-135-4893

View More Info

APL1-1RE-4349-3

CIRCUIT BREAKER

NSN, MFG P/N

5925011354893

NSN

5925-01-135-4893

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY LENGTH: 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM
BODY STYLE: 12A SINGLE POLE TYPE
BODY WIDTH: 0.750 INCHES MAXIMUM
BOSS HEIGHT: 0.135 INCHES MINIMUM AND 0.165 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.925 INCHES MINIMUM AND 1.955 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 3.700 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: CORROSION RESISTANT AND MOISTURE RESISTANT AND SHOCKPROOF AND VIBRATIONPROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 100.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 2000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.625 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 32.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 10.0 AC AND 3.0 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: PIN
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 250.0 AC AND 50.0 DC
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
THREAD PITCH DIAMETERS: 0.1177 TO 0.1214 INCHES
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.700 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

M39019/01-317

CIRCUIT BREAKER

NSN, MFG P/N

5925011354894

NSN

5925-01-135-4894

View More Info

M39019/01-317

CIRCUIT BREAKER

NSN, MFG P/N

5925011354894

NSN

5925-01-135-4894

MFG

MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 1.531 INCHES MINIMUM AND 1.562 INCHES MAXIMUM
BODY STYLE: 2A SINGLE POLE TYPE
BODY WIDTH: 0.594 INCHES MINIMUM AND 0.625 INCHES MAXIMUM
BUSHING LENGTH: 0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM
CASE MATERIAL: METAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.875 INCHES MINIMUM AND 0.906 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M39019/01-317
FEATURES PROVIDED: HIGH INRUSH PROTECTION
FREQUENCY IN HERTZ: 400.0 SINGLE LOCATION
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 50.0 GRAMS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND HERMETICALLY SEALED
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 3.0 AMPERES AC AND 3.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 300.0 AC AND 500.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING W/PANEL SEAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.669 INCHES MINIMUM AND 1.700 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.375 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-39019/1
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC AND 50.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-39019/1 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 WIRE HOOK
TEST DATA DOCUMENT: 81349-MIL-C-39019 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNEF
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.500 MINIMUM AT 200 PCT AND 9.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

M55629/3-068

CIRCUIT BREAKER

NSN, MFG P/N

5925011355272

NSN

5925-01-135-5272

View More Info

M55629/3-068

CIRCUIT BREAKER

NSN, MFG P/N

5925011355272

NSN

5925-01-135-5272

MFG

MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.479 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.469 INCHES MINIMUM AND 1.531 INCHES MAXIMUM
BOSS HEIGHT: 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M55629/3-068
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 400.0 ALL LOCATIONS
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 8.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.522 INCHES MINIMUM AND 2.553 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-55629/3
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-55629/3 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-55629 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.400 MINIMUM AT 200 PCT AND 1.500 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

AM1-B3-5-3

CIRCUIT BREAKER

NSN, MFG P/N

5925011357038

NSN

5925-01-135-7038

View More Info

AM1-B3-5-3

CIRCUIT BREAKER

NSN, MFG P/N

5925011357038

NSN

5925-01-135-7038

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.500 INCHES NOMINAL
BODY STYLE: 12A SINGLE POLE TYPE
BODY WIDTH: 0.750 INCHES NOMINAL
BOSS HEIGHT: 0.140 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.938 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.062 INCHES NOMINAL
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF AND FUNGUS PROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 5.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.611 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 65.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.180 MINIMUM AT 200 PCT AND 0.500 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

568B309G24

CIRCUIT BREAKER

NSN, MFG P/N

5925011359391

NSN

5925-01-135-9391

View More Info

568B309G24

CIRCUIT BREAKER

NSN, MFG P/N

5925011359391

NSN

5925-01-135-9391

MFG

GENERAL ELECTRIC COMPANY DBA GE STRUCTURED SERVICES DIV GENERAL ELECTRIC STRUCTURED SERVICES LP

Description

III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
RESET METHOD: MANUAL

AM12HKMG3-1-0-38

CIRCUIT BREAKER

NSN, MFG P/N

5925011362230

NSN

5925-01-136-2230

View More Info

AM12HKMG3-1-0-38

CIRCUIT BREAKER

NSN, MFG P/N

5925011362230

NSN

5925-01-136-2230

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY LENGTH: 2.510 INCHES MAXIMUM
BODY STYLE: 12A SINGLE POLE TYPE
BODY WIDTH: 0.730 INCHES MINIMUM AND 0.780 INCHES MAXIMUM
BOSS HEIGHT: 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M55629/2-018
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: SHOCK RESISTANT AND VIBRATION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 1.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.800 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-55629/2D
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-55629/2 GOVERNMENT SPECIFICATION
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 10.0 AC AND 2.0 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: TAB, SOLDER LUG
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 250.0 AC AND 50.0 DC
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-55629 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.130 MINIMUM AT 200 PCT AND 1.600 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

M55629/2-018

CIRCUIT BREAKER

NSN, MFG P/N

5925011362230

NSN

5925-01-136-2230

View More Info

M55629/2-018

CIRCUIT BREAKER

NSN, MFG P/N

5925011362230

NSN

5925-01-136-2230

MFG

MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY LENGTH: 2.510 INCHES MAXIMUM
BODY STYLE: 12A SINGLE POLE TYPE
BODY WIDTH: 0.730 INCHES MINIMUM AND 0.780 INCHES MAXIMUM
BOSS HEIGHT: 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M55629/2-018
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: SHOCK RESISTANT AND VIBRATION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 1.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.800 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-55629/2D
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-55629/2 GOVERNMENT SPECIFICATION
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 10.0 AC AND 2.0 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: TAB, SOLDER LUG
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 250.0 AC AND 50.0 DC
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-55629 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.130 MINIMUM AT 200 PCT AND 1.600 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

AM2-Z19-242

CIRCUIT BREAKER

NSN, MFG P/N

5925011362231

NSN

5925-01-136-2231

View More Info

AM2-Z19-242

CIRCUIT BREAKER

NSN, MFG P/N

5925011362231

NSN

5925-01-136-2231

MFG

LEVEL 3 COMMUNICATIONS LLC DIV FEDERAL MARKETS USE CAGE CODE 3A6U5 FOR CATALOGING.

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.510 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.437 INCHES MINIMUM AND 1.563 INCHES MAXIMUM
BOSS HEIGHT: 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M55629/3-242
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: SHOCK RESISTANT AND VIBRATION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 40.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.553 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-55629/3
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-55629/3 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-55629 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.130 MINIMUM AT 200 PCT AND 1.600 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

M55629/3-242

CIRCUIT BREAKER

NSN, MFG P/N

5925011362231

NSN

5925-01-136-2231

View More Info

M55629/3-242

CIRCUIT BREAKER

NSN, MFG P/N

5925011362231

NSN

5925-01-136-2231

MFG

MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.510 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.437 INCHES MINIMUM AND 1.563 INCHES MAXIMUM
BOSS HEIGHT: 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M55629/3-242
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: SHOCK RESISTANT AND VIBRATION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 40.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.553 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-55629/3
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-55629/3 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-55629 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.130 MINIMUM AT 200 PCT AND 1.600 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

632237-21

CIRCUIT BREAKER

NSN, MFG P/N

5925011362233

NSN

5925-01-136-2233

View More Info

632237-21

CIRCUIT BREAKER

NSN, MFG P/N

5925011362233

NSN

5925-01-136-2233

MFG

LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN MS2

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.479 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.205 INCHES MINIMUM AND 2.285 INCHES MAXIMUM
BOSS HEIGHT: 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M55629/5-034
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FREQUENCY IN HERTZ: 400.0 ALL LOCATIONS
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 3 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 3.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.522 INCHES MINIMUM AND 2.553 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-55629/5
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-55629/5 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 6 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-55629 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.200 MINIMUM AT 200 PCT AND 0.800 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 150.0 ALL LOCATIONS

AM333MG6-3-250-16-400

CIRCUIT BREAKER

NSN, MFG P/N

5925011362233

NSN

5925-01-136-2233

View More Info

AM333MG6-3-250-16-400

CIRCUIT BREAKER

NSN, MFG P/N

5925011362233

NSN

5925-01-136-2233

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.479 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.205 INCHES MINIMUM AND 2.285 INCHES MAXIMUM
BOSS HEIGHT: 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M55629/5-034
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FREQUENCY IN HERTZ: 400.0 ALL LOCATIONS
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 3 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 3.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.522 INCHES MINIMUM AND 2.553 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-55629/5
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-55629/5 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 6 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-55629 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.200 MINIMUM AT 200 PCT AND 0.800 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 150.0 ALL LOCATIONS

M55629/5-034

CIRCUIT BREAKER

NSN, MFG P/N

5925011362233

NSN

5925-01-136-2233

View More Info

M55629/5-034

CIRCUIT BREAKER

NSN, MFG P/N

5925011362233

NSN

5925-01-136-2233

MFG

MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.479 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.205 INCHES MINIMUM AND 2.285 INCHES MAXIMUM
BOSS HEIGHT: 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M55629/5-034
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FREQUENCY IN HERTZ: 400.0 ALL LOCATIONS
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 3 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 3.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.522 INCHES MINIMUM AND 2.553 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-55629/5
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-55629/5 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 6 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-55629 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.200 MINIMUM AT 200 PCT AND 0.800 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 150.0 ALL LOCATIONS

113-006-0005

CIRCUIT BREAKER

NSN, MFG P/N

5925011362234

NSN

5925-01-136-2234

View More Info

113-006-0005

CIRCUIT BREAKER

NSN, MFG P/N

5925011362234

NSN

5925-01-136-2234

MFG

NORTHROP GRUMMAN SYSTEMS CORPORATION DBA NORTHROP GRUMMAN SYSTEMS

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.510 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.437 INCHES MINIMUM AND 1.563 INCHES MAXIMUM
BOSS HEIGHT: 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M55629/3-241
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: SHOCK RESISTANT AND VIBRATION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 40.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.553 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-55629/3
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-55629/3 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-55629 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.200 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

190-240-201

CIRCUIT BREAKER

NSN, MFG P/N

5925011362234

NSN

5925-01-136-2234

View More Info

190-240-201

CIRCUIT BREAKER

NSN, MFG P/N

5925011362234

NSN

5925-01-136-2234

MFG

WOOD ELECTRIC OPERATIONS POTTER AND BRUMFIELD DIV AMF INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.510 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.437 INCHES MINIMUM AND 1.563 INCHES MAXIMUM
BOSS HEIGHT: 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M55629/3-241
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: SHOCK RESISTANT AND VIBRATION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 40.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.553 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-55629/3
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-55629/3 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-55629 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.200 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

AM33MG6-40-40-250V60HZ4

CIRCUIT BREAKER

NSN, MFG P/N

5925011362234

NSN

5925-01-136-2234

View More Info

AM33MG6-40-40-250V60HZ4

CIRCUIT BREAKER

NSN, MFG P/N

5925011362234

NSN

5925-01-136-2234

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.510 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.437 INCHES MINIMUM AND 1.563 INCHES MAXIMUM
BOSS HEIGHT: 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M55629/3-241
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: SHOCK RESISTANT AND VIBRATION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 40.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.553 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-55629/3
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-MIL-C-55629/3 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
TEST DATA DOCUMENT: 81349-MIL-C-55629 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.200 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS