Featured Products

My Quote Request

No products added yet

5925-01-084-2946

20 Products

AM1516MG3-15-125VACC3

CIRCUIT BREAKER

NSN, MFG P/N

5925010842946

NSN

5925-01-084-2946

View More Info

AM1516MG3-15-125VACC3

CIRCUIT BREAKER

NSN, MFG P/N

5925010842946

NSN

5925-01-084-2946

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 3.709 INCHES MINIMUM AND 3.729 INCHES MAXIMUM
BODY STYLE: 12A SINGLE POLE TYPE
BODY WIDTH: 0.980 INCHES MINIMUM AND 1.000 INCHES MAXIMUM
BOSS HEIGHT: 0.146 INCHES MINIMUM AND 0.166 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 3.053 INCHES MINIMUM AND 3.073 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.740 INCHES MINIMUM AND 2.760 INCHES MAXIMUM
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 2000.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 3.167 INCHES MINIMUM AND 3.311 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 125.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 4.000 NOMINAL AT 100 PCT AND 1.000 NOMINAL AT 125 PCT AND 0.300 NOMINAL AT 150 PCT AND 0.150 NOMINAL AT 200 PCT AND 0.030 NOMINAL AT 400 PCT AND 0.020 NOMINAL AT 500 PCT AND 0.003 NOMINAL AT 1000 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

12273297

CIRCUIT BREAKER

NSN, MFG P/N

5925010833042

NSN

5925-01-083-3042

View More Info

12273297

CIRCUIT BREAKER

NSN, MFG P/N

5925010833042

NSN

5925-01-083-3042

MFG

U S ARMY TANK AUTOMOTIVE COMMAND AMSTA-IM-MM

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: BETWEEN POLE ONE AND TWO
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY LENGTH: 1.562 INCHES MAXIMUM
BODY STYLE: 1B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.281 INCHES MAXIMUM
BUSHING LENGTH: 0.380 INCHES MAXIMUM
CASE MATERIAL: METAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.875 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.625 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 3.600 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: HERMETICALLY SEALED AND SHOCKPROOF AND VIBRATIONPROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MANUFACTURERS CODE: 19207
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 250.0 MILLIAMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 500.0 DC ALL LOCATIONS
MFR SOURCE CONTROLLING REFERENCE: 12273297
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING W/PANEL SEAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.780 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.375 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 50.0 DC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 0.5 AC AND 0.5 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: WIRE HOOK
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 120.0 AC AND 50.0 DC
TERMINAL TYPE AND QUANTITY: 4 WIRE HOOK
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNEF
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 135.0 ALL LOCATIONS

AP41-1RC-4931-1

CIRCUIT BREAKER

NSN, MFG P/N

5925010833042

NSN

5925-01-083-3042

View More Info

AP41-1RC-4931-1

CIRCUIT BREAKER

NSN, MFG P/N

5925010833042

NSN

5925-01-083-3042

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: BETWEEN POLE ONE AND TWO
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY LENGTH: 1.562 INCHES MAXIMUM
BODY STYLE: 1B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.281 INCHES MAXIMUM
BUSHING LENGTH: 0.380 INCHES MAXIMUM
CASE MATERIAL: METAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.875 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.625 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 3.600 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: HERMETICALLY SEALED AND SHOCKPROOF AND VIBRATIONPROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MANUFACTURERS CODE: 19207
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 250.0 MILLIAMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 500.0 DC ALL LOCATIONS
MFR SOURCE CONTROLLING REFERENCE: 12273297
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING W/PANEL SEAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.780 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.375 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 50.0 DC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 0.5 AC AND 0.5 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: WIRE HOOK
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 120.0 AC AND 50.0 DC
TERMINAL TYPE AND QUANTITY: 4 WIRE HOOK
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNEF
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 135.0 ALL LOCATIONS

XM61168

CIRCUIT BREAKER

NSN, MFG P/N

5925010833042

NSN

5925-01-083-3042

View More Info

XM61168

CIRCUIT BREAKER

NSN, MFG P/N

5925010833042

NSN

5925-01-083-3042

MFG

GENERAL DYNAMICS LAND SYSTEMS INC DBA GENERAL DYNAMICS LAND SYSTEMS DIVISION

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: BETWEEN POLE ONE AND TWO
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY LENGTH: 1.562 INCHES MAXIMUM
BODY STYLE: 1B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.281 INCHES MAXIMUM
BUSHING LENGTH: 0.380 INCHES MAXIMUM
CASE MATERIAL: METAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.875 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.625 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 3.600 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: HERMETICALLY SEALED AND SHOCKPROOF AND VIBRATIONPROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MANUFACTURERS CODE: 19207
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 250.0 MILLIAMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 500.0 DC ALL LOCATIONS
MFR SOURCE CONTROLLING REFERENCE: 12273297
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING W/PANEL SEAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.780 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.375 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 50.0 DC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS: 0.5 AC AND 0.5 DC
SWITCH LOCATION AND POSITION DESIGNATION: INTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: WIRE HOOK
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 120.0 AC AND 50.0 DC
TERMINAL TYPE AND QUANTITY: 4 WIRE HOOK
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNEF
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 135.0 ALL LOCATIONS

ST5M1649-007

CIRCUIT BREAKER

NSN, MFG P/N

5925010834816

NSN

5925-01-083-4816

View More Info

ST5M1649-007

CIRCUIT BREAKER

NSN, MFG P/N

5925010834816

NSN

5925-01-083-4816

MFG

BOEING COMPANY THE DBA BOEING

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.490 INCHES NOMINAL
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.265 INCHES MAXIMUM
BOSS HEIGHT: 0.150 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.940 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT FIRST LOCATION OVERCURRENT SECOND LOCATION OVERCURRENT THIRD LOCATION UNDERVOLTAGE FOURTH LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.060 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, THREE, AND FOUR LINKED
FREQUENCY IN HERTZ: 60.0 FIRST LOCATION 60.0 SECOND LOCATION 60.0 THIRD LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: CORROSION RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 4 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 10.0 AMPERES AC FIRST LOCATION 10.0 AMPERES AC SECOND LOCATION 10.0 AMPERES AC THIRD LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 AC FIRST LOCATION 5000.0 AC SECOND LOCATION 5000.0 AC THIRD LOCATION 2000.0 DC FOURTH LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 8 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.491 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC FIRST LOCATION 250.0 AC SECOND LOCATION 250.0 AC THIRD LOCATION 28.0 DC FOURTH LOCATION
POLE QUANTITY: 4
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 8 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.990 NOMINAL AT 200 PCT FIRST LOCATION 0.990 NOMINAL AT 200 PCT SECOND LOCATION 0.990 NOMINAL AT 200 PCT THIRD LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY FIRST LOCATION TIME DELAY SECOND LOCATION TIME DELAY THIRD LOCATION INSTANTANEOUS FOURTH LOCATION
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

UPL-1111-5242-7

CIRCUIT BREAKER

NSN, MFG P/N

5925010834816

NSN

5925-01-083-4816

View More Info

UPL-1111-5242-7

CIRCUIT BREAKER

NSN, MFG P/N

5925010834816

NSN

5925-01-083-4816

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.490 INCHES NOMINAL
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.265 INCHES MAXIMUM
BOSS HEIGHT: 0.150 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.940 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.750 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT FIRST LOCATION OVERCURRENT SECOND LOCATION OVERCURRENT THIRD LOCATION UNDERVOLTAGE FOURTH LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.060 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, THREE, AND FOUR LINKED
FREQUENCY IN HERTZ: 60.0 FIRST LOCATION 60.0 SECOND LOCATION 60.0 THIRD LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: CORROSION RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 4 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 10.0 AMPERES AC FIRST LOCATION 10.0 AMPERES AC SECOND LOCATION 10.0 AMPERES AC THIRD LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 AC FIRST LOCATION 5000.0 AC SECOND LOCATION 5000.0 AC THIRD LOCATION 2000.0 DC FOURTH LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 8 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.491 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC FIRST LOCATION 250.0 AC SECOND LOCATION 250.0 AC THIRD LOCATION 28.0 DC FOURTH LOCATION
POLE QUANTITY: 4
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 8 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.990 NOMINAL AT 200 PCT FIRST LOCATION 0.990 NOMINAL AT 200 PCT SECOND LOCATION 0.990 NOMINAL AT 200 PCT THIRD LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY FIRST LOCATION TIME DELAY SECOND LOCATION TIME DELAY THIRD LOCATION INSTANTANEOUS FOURTH LOCATION
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

202-66-3

BREAKER CAP,CIRCUIT

NSN, MFG P/N

5925010835897

NSN

5925-01-083-5897

View More Info

202-66-3

BREAKER CAP,CIRCUIT

NSN, MFG P/N

5925010835897

NSN

5925-01-083-5897

MFG

PARAMOUNT PLASTICS INC

Description

DESIGN CONTROL REFERENCE: 20266-3
GENERAL CHARACTERISTICS ITEM DESCRIPTION: PLASTIC SPLIT RING COLOR CODED TO IDENTIFY CIRCUIT BREAKER COLOR WHITE . OUTSIDE DIA.0.594IN
MANUFACTURERS CODE: 07RZ7
THE MANUFACTURERS DATA:

20266-3

BREAKER CAP,CIRCUIT

NSN, MFG P/N

5925010835897

NSN

5925-01-083-5897

View More Info

20266-3

BREAKER CAP,CIRCUIT

NSN, MFG P/N

5925010835897

NSN

5925-01-083-5897

MFG

DANCE AIR INC

Description

DESIGN CONTROL REFERENCE: 20266-3
GENERAL CHARACTERISTICS ITEM DESCRIPTION: PLASTIC SPLIT RING COLOR CODED TO IDENTIFY CIRCUIT BREAKER COLOR WHITE . OUTSIDE DIA.0.594IN
MANUFACTURERS CODE: 07RZ7
THE MANUFACTURERS DATA:

202-66-2

BREAKER CAP,CIRCUIT

NSN, MFG P/N

5925010835900

NSN

5925-01-083-5900

View More Info

202-66-2

BREAKER CAP,CIRCUIT

NSN, MFG P/N

5925010835900

NSN

5925-01-083-5900

MFG

DANCE AIR INC

Description

DESIGN CONTROL REFERENCE: 20266-2
GENERAL CHARACTERISTICS ITEM DESCRIPTION: PLASTIC SPLIT RING COLOR CODED TO IDENTIFY CIRCUIT BREAKER COLOR YELLO W. OUTSIDE DIA.0.594IN
MANUFACTURERS CODE: 1N6X0
THE MANUFACTURERS DATA:

202-66-2YELLOW

BREAKER CAP,CIRCUIT

NSN, MFG P/N

5925010835900

NSN

5925-01-083-5900

View More Info

202-66-2YELLOW

BREAKER CAP,CIRCUIT

NSN, MFG P/N

5925010835900

NSN

5925-01-083-5900

MFG

KRISMARK GROUP INC.

Description

DESIGN CONTROL REFERENCE: 20266-2
GENERAL CHARACTERISTICS ITEM DESCRIPTION: PLASTIC SPLIT RING COLOR CODED TO IDENTIFY CIRCUIT BREAKER COLOR YELLO W. OUTSIDE DIA.0.594IN
MANUFACTURERS CODE: 1N6X0
THE MANUFACTURERS DATA:

AM1516MG3-20-115VACC3

CIRCUIT BREAKER

NSN, MFG P/N

5925010836499

NSN

5925-01-083-6499

View More Info

AM1516MG3-20-115VACC3

CIRCUIT BREAKER

NSN, MFG P/N

5925010836499

NSN

5925-01-083-6499

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 3.719 INCHES NOMINAL
BODY STYLE: 12A SINGLE POLE TYPE
BODY WIDTH: 0.990 INCHES NOMINAL
BOSS HEIGHT: 0.156 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 3.063 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.750 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III ARC QUENCHING METHOD: AIR
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 2000.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 3.239 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 115.0 AC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.300 MINIMUM AT 200 PCT AND 1.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 150.0 SINGLE LOCATION

AM1516MG3-20-28VDCC2

CIRCUIT BREAKER

NSN, MFG P/N

5925010836500

NSN

5925-01-083-6500

View More Info

AM1516MG3-20-28VDCC2

CIRCUIT BREAKER

NSN, MFG P/N

5925010836500

NSN

5925-01-083-6500

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 3.719 INCHES NOMINAL
BODY STYLE: 12A SINGLE POLE TYPE
BODY WIDTH: 0.990 INCHES NOMINAL
BOSS HEIGHT: 0.156 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 3.063 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.750 INCHES NOMINAL
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 3.239 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.500 MINIMUM AT 200 PCT AND 7.500 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 150.0 SINGLE LOCATION

280-0034-01

CIRCUIT BREAKER

NSN, MFG P/N

5925010839946

NSN

5925-01-083-9946

View More Info

280-0034-01

CIRCUIT BREAKER

NSN, MFG P/N

5925010839946

NSN

5925-01-083-9946

MFG

CETEC BROADCAST GROUP DIV OF CETEC CORP

Description

III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
RESET METHOD: MANUAL

AM333-35-250-4-60

CIRCUIT BREAKER

NSN, MFG P/N

5925010840058

NSN

5925-01-084-0058

View More Info

AM333-35-250-4-60

CIRCUIT BREAKER

NSN, MFG P/N

5925010840058

NSN

5925-01-084-0058

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.240 INCHES MINIMUM AND 2.260 INCHES MAXIMUM
BOSS HEIGHT: 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: AIR
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 3 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 35.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.433 INCHES MINIMUM AND 2.492 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 6 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 4.000 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 150.0 ALL LOCATIONS

4014440-01

CIRCUIT BREAKER

NSN, MFG P/N

5925010840777

NSN

5925-01-084-0777

View More Info

4014440-01

CIRCUIT BREAKER

NSN, MFG P/N

5925010840777

NSN

5925-01-084-0777

MFG

RAYTHEON TECHNICAL SERVICES COMPANY

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE TWO
BODY HEIGHT: 3.338 INCHES NOMINAL
BODY LENGTH: 10.000 INCHES NOMINAL
BODY STYLE: 11B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 4.125 INCHES NOMINAL
BOSS HEIGHT: 0.250 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 9.125 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 1.375 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: UNDERVOLTAGE ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 9.125 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.375 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 200.0 AMPERES AC AND 200.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 22000.0 AC AND 10000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 UNTHREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 600.0 AC AND 250.0 DC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 6 THREADED STUD
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 480.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
UNTHREADED MOUNTING HOLE DIAMETER: 0.188 INCHES NOMINAL

KB-3200

CIRCUIT BREAKER

NSN, MFG P/N

5925010840777

NSN

5925-01-084-0777

View More Info

KB-3200

CIRCUIT BREAKER

NSN, MFG P/N

5925010840777

NSN

5925-01-084-0777

MFG

EATON CORP OPNS & TECHNICAL CENTER

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE TWO
BODY HEIGHT: 3.338 INCHES NOMINAL
BODY LENGTH: 10.000 INCHES NOMINAL
BODY STYLE: 11B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 4.125 INCHES NOMINAL
BOSS HEIGHT: 0.250 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 9.125 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 1.375 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: UNDERVOLTAGE ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 9.125 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.375 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 200.0 AMPERES AC AND 200.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 22000.0 AC AND 10000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 UNTHREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 600.0 AC AND 250.0 DC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 6 THREADED STUD
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 480.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
UNTHREADED MOUNTING HOLE DIAMETER: 0.188 INCHES NOMINAL

KB3200

CIRCUIT BREAKER

NSN, MFG P/N

5925010840777

NSN

5925-01-084-0777

View More Info

KB3200

CIRCUIT BREAKER

NSN, MFG P/N

5925010840777

NSN

5925-01-084-0777

MFG

EATON CORPORATION DBA FLUID POWER DIV DIV POWER AND LOAD MANAGEMENT SYSTEMS

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE TWO
BODY HEIGHT: 3.338 INCHES NOMINAL
BODY LENGTH: 10.000 INCHES NOMINAL
BODY STYLE: 11B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 4.125 INCHES NOMINAL
BOSS HEIGHT: 0.250 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 9.125 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 1.375 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: UNDERVOLTAGE ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 9.125 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.375 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 200.0 AMPERES AC AND 200.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 22000.0 AC AND 10000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 UNTHREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 600.0 AC AND 250.0 DC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 6 THREADED STUD
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 480.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
UNTHREADED MOUNTING HOLE DIAMETER: 0.188 INCHES NOMINAL

KB3200WITH120VACUVR

CIRCUIT BREAKER

NSN, MFG P/N

5925010840777

NSN

5925-01-084-0777

View More Info

KB3200WITH120VACUVR

CIRCUIT BREAKER

NSN, MFG P/N

5925010840777

NSN

5925-01-084-0777

MFG

EATON CORPORATION

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE TWO
BODY HEIGHT: 3.338 INCHES NOMINAL
BODY LENGTH: 10.000 INCHES NOMINAL
BODY STYLE: 11B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 4.125 INCHES NOMINAL
BOSS HEIGHT: 0.250 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 9.125 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 1.375 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: UNDERVOLTAGE ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 9.125 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.375 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 200.0 AMPERES AC AND 200.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 22000.0 AC AND 10000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 UNTHREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 600.0 AC AND 250.0 DC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 6 THREADED STUD
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 480.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
UNTHREADED MOUNTING HOLE DIAMETER: 0.188 INCHES NOMINAL

13216E6205-8

CIRCUIT BREAKER

NSN, MFG P/N

5925010842370

NSN

5925-01-084-2370

View More Info

13216E6205-8

CIRCUIT BREAKER

NSN, MFG P/N

5925010842370

NSN

5925-01-084-2370

MFG

CECOM LR CENTER

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.000 INCHES NOMINAL
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.250 INCHES NOMINAL
BOSS HEIGHT: 0.130 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.559 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 1.660 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.660 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FREQUENCY IN HERTZ: 400.0 ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 3 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 17.7 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.090 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 208.0 AC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.500 MINIMUM AT 200 PCT AND 4.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

JA3-218-8

CIRCUIT BREAKER

NSN, MFG P/N

5925010842370

NSN

5925-01-084-2370

View More Info

JA3-218-8

CIRCUIT BREAKER

NSN, MFG P/N

5925010842370

NSN

5925-01-084-2370

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.000 INCHES NOMINAL
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.250 INCHES NOMINAL
BOSS HEIGHT: 0.130 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.559 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 1.660 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.660 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.750 INCHES NOMINAL
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FREQUENCY IN HERTZ: 400.0 ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 3 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 17.7 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.090 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 208.0 AC ALL LOCATIONS
POLE QUANTITY: 3
RESET METHOD: MANUAL
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.500 MINIMUM AT 200 PCT AND 4.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS