CF3B015

CIRCUIT BREAKER

NSN, MFG P/N

5925008668548

NSN

5925-00-866-8548

View More Info

CF3B015

CIRCUIT BREAKER

NSN, MFG P/N

5925008668548

NSN

5925-00-866-8548

MFG

SPD ELECTRICAL SYSTEMS INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE TWO
BODY LENGTH: 11.937 INCHES NOMINAL
BODY STYLE: 16B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 4.500 INCHES NOMINAL
BOSS HEIGHT: 0.187 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 10.687 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 1.500 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 10.687 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.500 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES AC AND 15.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 120000.0 AC AND 100000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 UNTHREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 600.0 AC AND 250.0 DC ALL LOCATIONS
OVERALL HEIGHT: 4.812 INCHES NOMINAL
POLE QUANTITY: 3
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 6 COMPRESSION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: ANY ACCEPTABLE ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
UNTHREADED MOUNTING HOLE DIAMETER: 0.250 INCHES NOMINAL

2315739P53

CIRCUIT BREAKER

NSN, MFG P/N

5925008658964

NSN

5925-00-865-8964

View More Info

2315739P53

CIRCUIT BREAKER

NSN, MFG P/N

5925008658964

NSN

5925-00-865-8964

MFG

NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER

Description

ACTUATOR FUNCTION: RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 1.875 INCHES NOMINAL
BODY STYLE: 1B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.531 INCHES NOMINAL
BUSHING LENGTH: 0.340 INCHES NOMINAL
CASE MATERIAL: METAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.625 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.875 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DESIGN CONTROL REFERENCE: 2315739P53
FREQUENCY IN HERTZ: 400.0 ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: HERMETICALLY SEALED
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MANUFACTURERS CODE: 10001
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 5.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 300.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING W/PANEL SEAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.855 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.375 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 230.0 AC ALL LOCATIONS
POLE QUANTITY: 3
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS: AS DIFFERENTIATED BY SPECIAL TEST FEATURES
RESET METHOD: MANUAL
SPECIAL TEST FEATURES: NAVORD OD36190
TERMINAL TYPE AND QUANTITY: 6 WIRE HOOK
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNEF
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.100 MINIMUM AT 200 PCT AND 1.200 MAXIMUM AT 200 PCT AND 0.030 MINIMUM AT 300 PCT AND 0.440 MAXIMUM AT 300 PCT AND 0.010 MINIMUM AT 400 PCT AND 0.210 MAXIMUM AT 400 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
ULTIMATE TRIP TIME PER POLE IN SECONDS: 0.500 MINIMUM AND 5.000 MAXIMUM ALL LOCATIONS

2315741P18

CIRCUIT BREAKER

NSN, MFG P/N

5925008658967

NSN

5925-00-865-8967

View More Info

2315741P18

CIRCUIT BREAKER

NSN, MFG P/N

5925008658967

NSN

5925-00-865-8967

MFG

NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER

Description

ACTUATOR FUNCTION: RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 1.531 INCHES NOMINAL
BODY STYLE: 1B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.250 INCHES NOMINAL
BUSHING LENGTH: 0.340 INCHES NOMINAL
CASE MATERIAL: METAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.875 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.625 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DESIGN CONTROL REFERENCE: 2315741P18
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: HERMETICALLY SEALED
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MANUFACTURERS CODE: 10001
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 10.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 500.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING W/PANEL SEAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.855 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.375 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 50.0 DC ALL LOCATIONS
POLE QUANTITY: 2
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS: AS DIFFERENTIATED BY SPECIAL TEST FEATURES
RESET METHOD: MANUAL
SPECIAL TEST FEATURES: NAVORD OD36190
TERMINAL TYPE AND QUANTITY: 4 WIRE HOOK
THE MANUFACTURERS DATA:
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNEF
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.580 MINIMUM AT 200 PCT AND 6.000 MAXIMUM AT 200 PCT AND 0.080 MINIMUM AT 300 PCT AND 1.600 MAXIMUM AT 300 PCT AND 0.010 MINIMUM AT 400 PCT AND 0.630 MAXIMUM AT 400 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS
ULTIMATE TRIP TIME PER POLE IN SECONDS: 2.400 MINIMUM AND 42.000 MAXIMUM ALL LOCATIONS

7274-2

CIRCUIT BREAKER

NSN, MFG P/N

5925008659095

NSN

5925-00-865-9095

View More Info

7274-2

CIRCUIT BREAKER

NSN, MFG P/N

5925008659095

NSN

5925-00-865-9095

MFG

SENSATA TECHNOLOGIES INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 0.750 INCHES NOMINAL
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.562 INCHES NOMINAL
BUSHING LENGTH: 0.359 INCHES NOMINAL
CASE MATERIAL: METAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.593 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 480.0 SINGLE LOCATION
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF AND WATERTIGHT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 1.0 AMPERES AC AND 1.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: ANY ACCEPTABLE SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.302 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.438 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 115.0 AC AND 30.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 20.000 NOMINAL AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 85.0 DEG CELSIUS MAXIMUM SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 145.0 SINGLE LOCATION

840113-04

CIRCUIT BREAKER

NSN, MFG P/N

5925008659095

NSN

5925-00-865-9095

View More Info

840113-04

CIRCUIT BREAKER

NSN, MFG P/N

5925008659095

NSN

5925-00-865-9095

MFG

BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 0.750 INCHES NOMINAL
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.562 INCHES NOMINAL
BUSHING LENGTH: 0.359 INCHES NOMINAL
CASE MATERIAL: METAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.593 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 480.0 SINGLE LOCATION
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF AND WATERTIGHT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 1.0 AMPERES AC AND 1.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: ANY ACCEPTABLE SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.302 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.438 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 115.0 AC AND 30.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 20.000 NOMINAL AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 85.0 DEG CELSIUS MAXIMUM SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 145.0 SINGLE LOCATION

NEF212020

CIRCUIT BREAKER

NSN, MFG P/N

5925008659618

NSN

5925-00-865-9618

View More Info

NEF212020

CIRCUIT BREAKER

NSN, MFG P/N

5925008659618

NSN

5925-00-865-9618

MFG

CHALLENGER ACQUISITION CORP ENGINEERED DISTRIBUTION PRODUCTS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY HEIGHT: 3.406 INCHES NOMINAL
BODY LENGTH: 6.219 INCHES NOMINAL
BODY STYLE: 9A SINGLE POLE TYPE
BODY WIDTH: 1.375 INCHES NOMINAL
BOSS HEIGHT: 0.203 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 5.125 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 5.219 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.125 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: GENERAL PURPOSE
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES AC AND 20.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 14000.0 AC AND 10000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 4 SLOT
MOUNTING SLOT WIDTH: 0.250 INCHES NOMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 277.0 AC AND 125.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 COMPRESSION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 24.000 MINIMUM AT 200 PCT AND 65.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS AND TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL-MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 140.0 SINGLE LOCATION

NEF213020

CIRCUIT BREAKER

NSN, MFG P/N

5925008659618

NSN

5925-00-865-9618

View More Info

NEF213020

CIRCUIT BREAKER

NSN, MFG P/N

5925008659618

NSN

5925-00-865-9618

MFG

CHALLENGER ELECTRICAL EQUIPMENT CORP

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY HEIGHT: 3.406 INCHES NOMINAL
BODY LENGTH: 6.219 INCHES NOMINAL
BODY STYLE: 9A SINGLE POLE TYPE
BODY WIDTH: 1.375 INCHES NOMINAL
BOSS HEIGHT: 0.203 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 5.125 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 5.219 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 1.125 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: GENERAL PURPOSE
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 20.0 AMPERES AC AND 20.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 14000.0 AC AND 10000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 4 SLOT
MOUNTING SLOT WIDTH: 0.250 INCHES NOMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 277.0 AC AND 125.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 COMPRESSION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 24.000 MINIMUM AT 200 PCT AND 65.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS AND TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL-MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 140.0 SINGLE LOCATION

5925008662198

CIRCUIT BREAKER

NSN, MFG P/N

5925008662198

NSN

5925-00-866-2198

View More Info

5925008662198

CIRCUIT BREAKER

NSN, MFG P/N

5925008662198

NSN

5925-00-866-2198

MFG

E.C.A ETABLISSEMENT CENTRAL DES APPROVISIONNEMENTS DES FORCES ARMEES

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 1.500 INCHES NOMINAL
BODY STYLE: 2A SINGLE POLE TYPE
BODY WIDTH: 0.640 INCHES MAXIMUM
BUSHING LENGTH: 0.625 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.875 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: SHOCKPROOF AND VIBRATIONPROOF AND HERMETICALLY SEALED
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 1.5 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1500.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.605 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.375 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 50.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 WIRE HOOK
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNEF
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.090 MINIMUM AT 200 PCT AND 0.600 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

77-109-2-1-5-500DC

CIRCUIT BREAKER

NSN, MFG P/N

5925008662198

NSN

5925-00-866-2198

View More Info

77-109-2-1-5-500DC

CIRCUIT BREAKER

NSN, MFG P/N

5925008662198

NSN

5925-00-866-2198

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 1.500 INCHES NOMINAL
BODY STYLE: 2A SINGLE POLE TYPE
BODY WIDTH: 0.640 INCHES MAXIMUM
BUSHING LENGTH: 0.625 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.875 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: SHOCKPROOF AND VIBRATIONPROOF AND HERMETICALLY SEALED
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 1.5 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1500.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.605 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.375 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 50.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 WIRE HOOK
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNEF
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.090 MINIMUM AT 200 PCT AND 0.600 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

807141-2

CIRCUIT BREAKER

NSN, MFG P/N

5925008662198

NSN

5925-00-866-2198

View More Info

807141-2

CIRCUIT BREAKER

NSN, MFG P/N

5925008662198

NSN

5925-00-866-2198

MFG

L-3 COMMUNICATIONS CINCINNATI ELECTRONICS CORPORATION

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 1.500 INCHES NOMINAL
BODY STYLE: 2A SINGLE POLE TYPE
BODY WIDTH: 0.640 INCHES MAXIMUM
BUSHING LENGTH: 0.625 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.875 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: SHOCKPROOF AND VIBRATIONPROOF AND HERMETICALLY SEALED
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 1.5 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1500.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.605 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.375 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 50.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 WIRE HOOK
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNEF
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.090 MINIMUM AT 200 PCT AND 0.600 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

AP11B

CIRCUIT BREAKER

NSN, MFG P/N

5925008662198

NSN

5925-00-866-2198

View More Info

AP11B

CIRCUIT BREAKER

NSN, MFG P/N

5925008662198

NSN

5925-00-866-2198

MFG

SENSATA TECHNOLOGIES MARYLAND INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 1.500 INCHES NOMINAL
BODY STYLE: 2A SINGLE POLE TYPE
BODY WIDTH: 0.640 INCHES MAXIMUM
BUSHING LENGTH: 0.625 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.875 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: SHOCKPROOF AND VIBRATIONPROOF AND HERMETICALLY SEALED
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 1.5 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1500.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.605 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.375 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 50.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 WIRE HOOK
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNEF
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.090 MINIMUM AT 200 PCT AND 0.600 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

SM-D-414917-2

CIRCUIT BREAKER

NSN, MFG P/N

5925008662198

NSN

5925-00-866-2198

View More Info

SM-D-414917-2

CIRCUIT BREAKER

NSN, MFG P/N

5925008662198

NSN

5925-00-866-2198

MFG

US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 1.500 INCHES NOMINAL
BODY STYLE: 2A SINGLE POLE TYPE
BODY WIDTH: 0.640 INCHES MAXIMUM
BUSHING LENGTH: 0.625 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.875 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: SHOCKPROOF AND VIBRATIONPROOF AND HERMETICALLY SEALED
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 1.5 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1500.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.605 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.375 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 50.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 WIRE HOOK
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNEF
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.090 MINIMUM AT 200 PCT AND 0.600 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 SINGLE LOCATION

10105407

CIRCUIT BREAKER

NSN, MFG P/N

5925008662837

NSN

5925-00-866-2837

View More Info

10105407

CIRCUIT BREAKER

NSN, MFG P/N

5925008662837

NSN

5925-00-866-2837

MFG

U S ARMY AVIATION AND MISSILE COMMAND

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.490 INCHES MINIMUM AND 1.510 INCHES MAXIMUM
BOSS HEIGHT: 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 7.5 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 3000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.689 INCHES MINIMUM AND 2.813 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 24.0 DC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.400 MINIMUM AT 200 PCT AND 7.500 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 150.0 ALL LOCATIONS

AM33MG6-7-5-24VDC4

CIRCUIT BREAKER

NSN, MFG P/N

5925008662837

NSN

5925-00-866-2837

View More Info

AM33MG6-7-5-24VDC4

CIRCUIT BREAKER

NSN, MFG P/N

5925008662837

NSN

5925-00-866-2837

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 1.490 INCHES MINIMUM AND 1.510 INCHES MAXIMUM
BOSS HEIGHT: 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE AND TWO LINKED
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 2 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 7.5 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 3000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.689 INCHES MINIMUM AND 2.813 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 24.0 DC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 THREADED STUD
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.400 MINIMUM AT 200 PCT AND 7.500 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 150.0 ALL LOCATIONS

111-201-101

CIRCUIT BREAKER

NSN, MFG P/N

5925008662960

NSN

5925-00-866-2960

View More Info

111-201-101

CIRCUIT BREAKER

NSN, MFG P/N

5925008662960

NSN

5925-00-866-2960

MFG

WOOD ELECTRIC OPERATIONS POTTER AND BRUMFIELD DIV AMF INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 1.375 INCHES MAXIMUM
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.687 INCHES MAXIMUM
BUSHING LENGTH: 0.365 INCHES MINIMUM AND 0.385 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.010 INCHES MINIMUM AND 1.030 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 400.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: SHOCK RESISTANT AND VIBRATION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 1.0 AMPERES AC AND 1.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 100.0 AC AND 150.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.035 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.375 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC AND 32.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 TAB W/SCREW
TEST DATA DOCUMENT: 98571-830823 DRAWING
THREAD QUANTITY PER INCH: 24
THREAD SERIES DESIGNATOR: UNF
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.500 MINIMUM AT 200 PCT AND 1.800 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 135.0 SINGLE LOCATION

13-0550-0010

CIRCUIT BREAKER

NSN, MFG P/N

5925008662960

NSN

5925-00-866-2960

View More Info

13-0550-0010

CIRCUIT BREAKER

NSN, MFG P/N

5925008662960

NSN

5925-00-866-2960

MFG

COMPUNETICS INC . DIV PRINTED CIRCUIT BOARDS

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 1.375 INCHES MAXIMUM
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.687 INCHES MAXIMUM
BUSHING LENGTH: 0.365 INCHES MINIMUM AND 0.385 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.010 INCHES MINIMUM AND 1.030 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 400.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: SHOCK RESISTANT AND VIBRATION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 1.0 AMPERES AC AND 1.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 100.0 AC AND 150.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.035 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.375 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC AND 32.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 TAB W/SCREW
TEST DATA DOCUMENT: 98571-830823 DRAWING
THREAD QUANTITY PER INCH: 24
THREAD SERIES DESIGNATOR: UNF
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.500 MINIMUM AT 200 PCT AND 1.800 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 135.0 SINGLE LOCATION

830823-2

CIRCUIT BREAKER

NSN, MFG P/N

5925008662960

NSN

5925-00-866-2960

View More Info

830823-2

CIRCUIT BREAKER

NSN, MFG P/N

5925008662960

NSN

5925-00-866-2960

MFG

TELEDYNE TECHNOLOGIES INC DBA TELEDYNE CONTROLS DIV TELEDYNE CONTROLS

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 1.375 INCHES MAXIMUM
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.687 INCHES MAXIMUM
BUSHING LENGTH: 0.365 INCHES MINIMUM AND 0.385 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.010 INCHES MINIMUM AND 1.030 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 400.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: SHOCK RESISTANT AND VIBRATION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 1.0 AMPERES AC AND 1.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 100.0 AC AND 150.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.035 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.375 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC AND 32.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 TAB W/SCREW
TEST DATA DOCUMENT: 98571-830823 DRAWING
THREAD QUANTITY PER INCH: 24
THREAD SERIES DESIGNATOR: UNF
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.500 MINIMUM AT 200 PCT AND 1.800 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 135.0 SINGLE LOCATION

842-201-101

CIRCUIT BREAKER

NSN, MFG P/N

5925008662960

NSN

5925-00-866-2960

View More Info

842-201-101

CIRCUIT BREAKER

NSN, MFG P/N

5925008662960

NSN

5925-00-866-2960

MFG

TYCO ELECTRONICS CORPORATION

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 1.375 INCHES MAXIMUM
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.687 INCHES MAXIMUM
BUSHING LENGTH: 0.365 INCHES MINIMUM AND 0.385 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.010 INCHES MINIMUM AND 1.030 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 400.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: SHOCK RESISTANT AND VIBRATION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 1.0 AMPERES AC AND 1.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 100.0 AC AND 150.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.035 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.375 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC AND 32.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 TAB W/SCREW
TEST DATA DOCUMENT: 98571-830823 DRAWING
THREAD QUANTITY PER INCH: 24
THREAD SERIES DESIGNATOR: UNF
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 0.500 MINIMUM AT 200 PCT AND 1.800 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 135.0 SINGLE LOCATION

577R897H02

CIRCUIT BREAKER

NSN, MFG P/N

5925008663106

NSN

5925-00-866-3106

View More Info

577R897H02

CIRCUIT BREAKER

NSN, MFG P/N

5925008663106

NSN

5925-00-866-3106

MFG

NORTHROP GRUMMAN SYSTEMS CORPORATION DIV NORTHROP GRUMMAN SYSTEMS CORPORATION ELECTRONIC SYSTEMS

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY LENGTH: 1.750 INCHES NOMINAL
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.625 INCHES NOMINAL
BUSHING LENGTH: 0.290 INCHES NOMINAL
CASE MATERIAL: METAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.341 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 2.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING W/PANEL SEAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.638 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.469 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 32.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, SINGLE THROW, NORMALLY CLOSED
SWITCH CURRENT RATING AND TYPE IN AMPS: 7.0 AC AND 7.0 DC
SWITCH LOCATION AND POSITION DESIGNATION: EXTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: TAB, SOLDER LUG
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 130.0 AC AND 28.0 DC
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.000 NOMINAL AT 200 PCT AND 0.100 NOMINAL AT 325 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 135.0 SINGLE LOCATION

7MC12-4-2

CIRCUIT BREAKER

NSN, MFG P/N

5925008663106

NSN

5925-00-866-3106

View More Info

7MC12-4-2

CIRCUIT BREAKER

NSN, MFG P/N

5925008663106

NSN

5925-00-866-3106

MFG

SENSATA TECHNOLOGIES INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY LENGTH: 1.750 INCHES NOMINAL
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.625 INCHES NOMINAL
BUSHING LENGTH: 0.290 INCHES NOMINAL
CASE MATERIAL: METAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.341 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 2.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING W/PANEL SEAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.638 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.469 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 32.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
SWITCH CONTACT ARRANGEMENT: SINGLE POLE, SINGLE THROW, NORMALLY CLOSED
SWITCH CURRENT RATING AND TYPE IN AMPS: 7.0 AC AND 7.0 DC
SWITCH LOCATION AND POSITION DESIGNATION: EXTERNAL AT POLE ONE
SWITCH TERMINAL TYPE: TAB, SOLDER LUG
SWITCH VOLTAGE RATING AND TYPE IN VOLTS: 130.0 AC AND 28.0 DC
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.000 NOMINAL AT 200 PCT AND 0.100 NOMINAL AT 325 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 135.0 SINGLE LOCATION